31 Oct
Wearable Cardiac Monitoring
Tudor Besleaga, Ph.D., and Jacob Skinner, D.Phil., Thrive Wearables, wrote in the current issue of meddeviceonline: “Cardiac monitoring is almost a standard feature of modern wearables but there are still opportunities to get better information and do more with the data. Seizing those opportunities could transform everything from medical care to athletic training and general well-being.
Cardiac monitoring has been around for over 100 years, but improved accuracy and wearable technology mean we can now get a better view of cardio performance not only in the hospital but also in the home, at work, or even while the wearer runs a marathon.
Turning this monitoring into actionable insights promises many benefits. Can we determine how well someone is recovering from surgery? Can we measure stress? And can we do so with a system that is low on user friction and high on user value? At present, the most accurate measurements come from the most cumbersome devices, and devices that are comfortable to wear tend not to offer the richest data.
The opportunity for the next generation of products and services is to further blur the distinctions between devices designed for medical professionals, performance athletes, and consumers. We have some obstacles to overcome before we get there, though.
Why Monitor More Than Heart Rate?
It’s worth starting by asking why we want to monitor heart signals with wearables in the first place. It is routine to monitor the heart dynamics of all kinds of patients. The cardiovascular system reveals how a patient is recovering from surgery, the effect of drugs, and more. Sudden changes can indicate serious problems.
Innovation in high-quality cardiac monitoring has also come from devices for athletes. For example, heart rate variability (HRV) – the change in the time between heart beats – and resting heart rate are both indicators of overall fitness, so monitoring of these metrics first appeared in wearables for professional athletes and serious amateurs. These filtered down into more affordable consumer devices pitched as more general lifestyle and well-being assistants.
As well as cardiac monitoring for overall health, some devices can warn of sudden changes in heart rate intervals or test for atrial fibrillation (AFib), a common but potentially dangerous heart abnormality. In a sign of how serious diagnostic tools are being integrated into consumer products, the Apple Watch has been approved as a medical device by the FDA in the U.S. and by other regulators.
ECG Versus PPG
Different use cases will have different ideal technologies and form factors. Essentially, though, wearable cardiac monitors rely on two technologies with different approaches and distinct strengths and weaknesses.
The first is the electrocardiogram (ECG), first developed in the late 19th century. This measures the electrical signal produced by the heart as it beats and is a good guide to heart function. Measurement can be cumbersome, however. A hospital might use a 12-lead ECG, but this restricts movement and needs professional assistance. The consumerization of these devices sacrifices some data resolution but allows them to be worn unobtrusively and comfortably on the wrist for spot measurements instead of continuous ones. In recent years, some smartwatches have added ECG sensors, primarily for detecting things like AFib. These work by sending an electrical signal through the body so the user must wear the watch on one hand and touch the case with the opposite hand to complete the circuit.
Outside the hospital or a testing lab, a chest strap ECG is the best option. This isn’t as accurate as the multiple lead approach but almost everything in this space is a trade-off between user friction and perceived value. The value here is mobility, but the friction comes from reduced accuracy. Moreover, most people don’t want to wear a chest strap for long periods. There isn’t enough value. Cardiologists have tried to get patients to wear all kinds of devices and, other than implanted ones, devices on the wrist are about the only acceptable form factor for most patients.
That works well if the wearer can remember, or be reminded, to perform the ECG regularly but most people would prefer unobtrusive background monitoring. That can be done with a photoplethysmogram (PPG), which was invented in the 1930s and uses a light shone through the skin to track blood flow. This offers insights into cardiac hemodynamics, such as blood pressure trends and cardiac output but also provides localized measurements, such as tissue oxygenation. A downside of this type of sensing is its susceptibility to movement-induced signal loss, particularly at the wrist, where it’s most commonly worn. However, the wrist is a good location for user experience and PPG sensors are now standard in fitness bands and smartwatches, also making the sensor price point increasingly low.
PPG and ECG can complement each other in monitoring the cardiovascular system. The former can be adapted to various form factors and provides long-term continuous measurements, while the latter is limited to chest-based, albeit accurate, continuous measurements and wrist-based spot measurements. It is not uncommon to see PPG watches monitoring alongside chest straps during periods of intense exercise. Or PPG watches using ECG watch spot measurements to obtain quick but reliable and easily comparable readings.
Again, there is a trade-off. A PPG sensor might be most comfortable on the wrist, but the wrist isn’t the ideal place to monitor blood flow. We move our arms, especially when we exercise, which disrupts the signal and means lost data. The system must estimate, or do without, the missing information.
The Next Generation Of Cardio Sensors
Sensors, particularly PPG sensors, are improving all the time, so we can be optimistic about future devices. Most manufacturers have iteratively improved the designs of their PPG sensor modules regularly in recent years, indicating the likelihood of more application options as they improve further.
There are off-the-shelf integrated solutions for measuring PPG or ECG and exporting the data via a serial bus. However, these commonly fall short in signal quality compared to the best in class. Most developers design their own sensor systems, by combining a sensor-body interface, analog front end (AFE), and microcontroller unit (MCU).
The sensor-body interface, which is either an optical front end (OFE) for PPG or electrodes for ECG, is where the most value could be added. The OFE consists of one or more light emitters, commonly LEDs, one or more light sensors, commonly photodiodes (PDs), and a mask to control the light between them. The mask must ensure light passes through the tissue, rather than reflecting straight to the PD, that minimal ambient light enters the sensor, and that good pressure is maintained against the tissue.
The sensor-body interface must be optimized for where it will measure. Red or infrared light is fine for a fingertip PPG, for example, but green light makes data from the wrist less susceptible to motion noise. Some chest devices use both green and red to assess pulses at different depths; the higher the wavelength, the deeper it penetrates.
It is not uncommon for sensors to use discrete components assembled with the mask. However, integrated solutions can save space and cost. These provide PDs with peak sensitivity at the same wavelength as the LEDs and can output three channels (green, red, infrared). One downside is that the distance between the light emitter and the receiver is fixed and typically optimised for wrist cardiac measurement applications. That distance might need to be increased for measuring higher up the arm or at the chest in deeper tissue.
AFEs have improved a lot recently, particularly in signal preprocessing. They can measure ambient light and exclude the baseline, operate LEDs at very low duty cycles, increase energy efficiency, and filter specific frequencies. Some even calculate heart rate intervals for HRV. Many off-the-shelf integrated circuits (ICs) now provide collections of PPG, ECG, or both via multiple channels. When measuring ECG, it is important to select an IC that is optimized for dry electrodes, whether polymer conductive ones, as in chest straps, or stainless steel, as in many watches.
It is important to establish before development how much processing and analysis of the raw signal will be done on the device versus on servers. A lot of memory can be saved if only specific metrics are required, such as HRV, rather than complete raw data.
Since these signals are very susceptible to movement-induced noise, it is common to record accelerometer or inertial measurement unit (IMU) data along with the cardiac data. Motion data can help identify corrupted signal intervals and improve battery life by turning off recordings during high-intensity motion.
For ECG recordings, the MCU will be the main power consumer. Integrated solutions (OFE, AFE, and MCU) do exist. However, they are not quite plug and play, as different form factors require optimization of sensor position and body interface. Furthermore, the onboard MCU means higher energy consumption. They also share limited processed data, as raw sensor data exposes these companies to intellectual property (IP) leak risks.
Medical device manufacturers could benefit from pursuing a hybrid agile approach when developing devices with cardiac sensors, as iterative sensor implementations are to be expected.”
Please find the complete article here.
For further information please get in touch with us:
+49-176-57694801